Quest AQ5001Pro IAQ monitors are actually two meters in
one.
All of our AQ5001Pro IAQ monitors include an AQ5000Pro
handheld monitor equipped with a Carbon Monoxide sensor
and a tough, tamper resistant, custom PelicanTM brand case.
When the AQ5000Pro is secured in the case it can be
left unattended for continuous long term IAQ monitoring. Not only does the
case protect the monitor during sampling, it also doubles as a durable
shipping container to protect your investment while in transit.
You can easily convert AQ5001Pro indoor air quality monitors from a continuous
portable IAQ meter to a handheld meter by simply opening the case and
removing the AQ5000Pro.
For pricing and availability information regarding the
purchase, service or calibration of AQ5001Pro IAQ monitors, please email Customer Service.
For answers to questions regarding installation, setup, operation,
maintenance or trouble-shooting of AQ5001Pro IAQ monitors, please email technical support.
Brochures Available:
English Version (pdf) 1.9M
Spanish Version (pdf) 750K
AQ5001Pro Technical Specifications
Measured Parameters:
Carbon Dioxide:
-
Detector NDIR (non-dispersive infrared)
-
Range User Selectable
-
0 to 5,000 and 0 to 20,000 ppm
-
Accuracy 0 to 5,000 ppm: +/-3% of reading +/-50 ppm
-
0 to 20,000 ppm: +/-3% of reading +/-300 ppm
Temperature Influence Additional +/-0.2% of reading
+/-2 ppm for each °C
-
Resolution 1 ppm (10 ppm above 10,000 ppm)
-
Response Time 22 seconds for 63% of final value; 70 seconds for
10-90% of 4000 ppm change
Relative Humidity:
-
Detector Capacitive
-
Range 0-100% non-condensing
-
Accuracy +/-3% @ 25°C
-
Resolution 0.1%
-
Response Time 50 seconds with min air flow of 1 mi/hr
-
(.45 meters/sec) through wand
Temperature:
Dew Point:
-
Range -65 oC/+60 °C
-
Resolution 0.1 °C
Gas:
-
Detector O2, CO, H2S, SO2, CL2, NO2, NO, HCN & NH3
-
Resolution 0.1, 0.5 or 1 ppm depending on sensor in use
Air Velocity:
-
Detector Hot-Wire
-
Range 0-20 m/s
-
Accuracy +/- 5%
-
Resolution 0.1 m/s
Linear:
Data Storage:
Display:
Real Time Clock:
Storage Rate:
Statistics Saved:
-
Up to 5 data values per sampling interval (CO2, temperature,
humidity, dew point, gas and linear and air velocity input)
Communications:
-
Format RS-232, 1 start, 8 data, 1 stop bit, no parity
-
Baud Rate 1200 to 38400
Printer Output:
Summary Report includes:
-
Separate reports for each logging session indicating
minimum, maximum & time of occurrence, elapsed time &
average per session.
-
Gas readings include:
TWA & STEL
Time History Report Includes:
All recorded data values with date & time stamp
Power:
-
Internal Power:
"AA" Alkaline Batteries - >15 hrs @ 25°C (77°F)
-
Rechargeable NiMH Battery Pack: 7 hrs @ 25°C (77°F)
(Data Retention 30 days in the event of low battery)
-
External Power:
+6.0 Vdc output AC power adapter, 120 VAC or 240v
Environments:
Size:
-
Enclosure Size 3.6 x 7.1 x 1.3" (9.1 x 18.0 x 3.3 cm)
-
Wand Size 11.8" (30cm) long, 1" (2.54 cm) diameter
Weight:

|
|