Quest is the System Solution for Noise Dosimeters

NEW
The Edge Cable Free Dosimeter

The Edge Cable Free Dosimeter
NEW
NoisePro® Noise Dosimeters
NoisePro Series Home Page
Product Comparison Guide
NoisePro Dosimeters
NoisePro DL Dosimeters
NoisePro DLX Dosimeters
NoisePro DLX-1 Dosimeters
Ordering Information
Sound Calibrators
Customer Support
Latest NoisePro Updates
Online Customer Support

Ask Technical Support
Ask Customer Service
Home
Quest Home Page

Noise Dosimeters - NoisePro DLX

Noise Dosimeter - NoisePro DLX

Do you need advanced statistical analysis of your noise exposure data?
Then the NoisePro® DLX should be your next noise dosimeter. This Type 2 noise dosimeter logs Lavg/Leq, FastMax, SlowMax, FastMin, SlowMin, Fast Ceiling Count, Slow Ceiling Count and Lpeak at selectable intervals from 1 second up to 1 hour.

It includes (4) virtual noise dosimeters to measure (4) separate noise standards. An impressive 128 x 64 pixel backlit LCD display and intelligent user interface provide easy access to data and setup information. Options include a vibrating alarm and boom microphone. Would you still like to go for other under-equipped noise exposure meters?

All NoisePro® noise dosimeters are compatible with QuestSuite Professional Software for advanced reporting and record keeping, a virtual docking station, calibration management and more.

Attention International Users:
The NoisePro® DLX noise dosimeter is available in: English, Spanish, German, French, and Italian.

Brochures Available:
English Version (pdf) 1.4M
Spanish Version (pdf) 150K

NoisePro® DLX Noise Dosimeter Technical Specifications

Measurement Range:

  • 40 to 110dB RMS
  • 70 to 140dB RMS
  • 115 to 143dB Peak

Dynamic Range:

  • 70dB RMS
  • 28dB Peak

Resolution:

  • Amplitude: 0.1dB
  • Dose Resolution:
    0.001% to 9999% Auto Scaling, (4) digits
  • Statistical Distribution Resolution:
    0.1dB Increments for Fast & Slow

Number of Channels:

  • (1) RMS
  • (1) Peak
  • Frequency Weighting per Channel:
    RMS A or C, Peak A, C, or Z

Parameters per Dosimeter:

  • Slow or Fast for Each or Impulse for All
  • 3, 4, 5 or 6dB Exchange Rate
  • Criterion Level:
    40 to 140db in 1dB Increments
  • Criterion Time:
    1 to 24 hrs in 1hr Increments
  • Personal Noise Exposure Level Times:
    1 to 18 hrs in 1 hr Increments
  • Threshold level:
    40 to 140dB in 1dB Increments
  • Upper Limit Value :
    40 to 140dB in 1dB Increments

Ceiling Limit Value per Unit:

  • (1) FastMax
  • (1) SlowMax
  • 40 to 140dB

Date & Time Format:

  • DD/MMM/YYY
  • HH:MM:SS AM/PM
  • 24 Hour Clock

Number of Setup Files in Memory:

  • (5) Factory Defined
  • (4) User Defined

Intrinsic Safety Agency Listing:

  • UL
  • cUL
  • ATEX
  • MSHA

Pending Intrinsic Safety Agency Listing:

  • SIMTARS

Product Standards:

  • CE Mark
  • EN 61252
  • ANSI S1.25

Power:

  • Optimally (70) hours from (2) AA disposable alkaline batteries
Environmental:
  • -10 to +50C, (+14 to 122F) Operating Range
  • -25 to +60C, (-13 to +140F) Storage Range
  • 0 to 95% Non Condensing Humidity Range

Mechanical:

  • IP-65 Rated Aluminum Case
  • 2.7" x 5" x 1.5" (68.6mm x 127mm x38.1mm)
  • 14ozs., (369g)